Most GE dryer codes point to a temperature sensor (thermistor), a door switch, a stuck button, a wiring problem or a blocked vent. On many models the codes are three digits (001 to 009); on others they start with F (F01 to F11). Vent alerts and long dry times you can often fix by cleaning the lint filter and vent duct, while thermistor, motor and control board codes need a technician.
GE dryers store a fault code when a sensor or part does not respond as expected. Depending on the model, the same fault may show as 001, E01 or F01, and some codes only appear when a technician enters service mode. Codes vary by model, so check your owner's manual or the tech sheet behind the dryer if what you see is not listed here. Unplug the dryer, and for gas models turn off the gas valve, before any hands-on check. This list combines the manufacturer's own documentation with codes reported by established repair-parts references (such as Sears PartsDirect, PartSelect and repair technicians' guides); those are marked "commonly reported" or "on some models".
GE Dryer error codes and what they mean
| Code | What it means | What to try |
|---|---|---|
000 |
No fault stored. Shown in service mode when there is nothing to report. | No repair needed. |
001 / 003 / F01 / F03 |
Inlet thermistor (temperature sensor near the heat source) is open or shorted. Call a technician |
Power off for a few minutes and restart. If the code returns, the thermistor or its wiring needs to be tested and replaced. |
002 / 004 / F02 / F04 |
Outlet thermistor (exhaust temperature sensor) is open or shorted. Call a technician |
Power off for a few minutes and restart. If the code returns, the outlet thermistor or its wiring needs service. |
tE (some models) |
Outlet thermistor circuit problem. The dryer stops to avoid overheating. Call a technician |
Power off and restart once. If it returns, a technician should test the thermistor and wiring. |
005 / F05 |
Main control board fault. Call a technician |
Unplug the dryer for about 3 minutes to reset the board. If the code comes back, the control board likely needs replacing. |
006 / F06 |
A button on the control panel is stuck. | Press each button firmly to free it. If the code stays, the control panel or board needs service. |
007 / F07 |
Power supply miswired: line 2 and neutral are reversed at the terminal block. Call a technician |
Do not open the terminal block yourself. Have an installer or electrician correct the power cord wiring. |
008 / 00d / F08 |
Door switch did not open over 5 cycles in a row (switch stuck closed). Call a technician |
Open and close the door firmly a few times. If the code returns, the door switch or its wiring needs replacing. |
009 (some models) |
Drive motor problem: the motor will not run, or will not shut off. Call a technician |
Unplug the dryer and make sure the drum turns by hand without binding. A technician should check the belt, motor and control relay. |
F09 (some models) |
Long dry times detected. | Clean the lint filter and check the vent duct for lint, crushing or a stuck outside flap. If drying is still slow, the heating system needs service. |
F010 / F10 (some models) |
The dryer was started with an empty drum. Not a hardware fault. | Add laundry and start a new cycle; the code clears. |
F011 / F11 (some models) |
The load is already dry. Not a hardware fault. | Start a new cycle with wet laundry; the code clears. |
Check Vent / vent alert |
On models with a vent sensor, airflow out of the dryer is low, so the vent is likely blocked. | Unplug the dryer, disconnect the duct and vacuum it out. Check that the outside hood flaps move freely and nothing is nesting in it. Clean the vent at least once a year. |
SENSE (scrolling) |
Normal on some models. The dryer is warming up and measuring exhaust temperature before showing time remaining. | No action needed. The time shown may change as the dryer adjusts to your vent. |
E00 / E01 (some newer models) |
On some newer models (such as DBVH512 and DCVH515): E00 means no error; E01 is a control memory (EEPROM) failure. Call a technician |
Turn off power at the breaker (or unplug) for 5 minutes, then restart. If the code comes back, call a technician. |
E02 / E03 / E04 / E05 (some newer models) |
Thermistor (temperature sensor) faults. Depending on model: E02 inlet thermistor shorted, E03 outlet thermistor shorted, E04 inlet thermistor open, E05 outlet thermistor open (DBVH512-type models); on some front-load models, E3 and E4 are the inlet thermistor open or shorted and E5 the outlet thermistor shorted. Call a technician |
Clean the lint screen and vent first, since poor airflow strains the sensors. If the code returns, call a technician. |
E1 / E2 (front-load) |
Some front-load models (such as DPVH880): user interface memory (E1) or power board memory (E2) read/write failure. Call a technician |
Turn off power at the breaker (or unplug) for 5 minutes, then restart. If the code comes back, call a technician. |
E10 |
Depending on model: no model-select connector detected on the power board (some front-load models), or commonly reported as a communication failure between the main board and the user interface. Call a technician |
Turn off power at the breaker (or unplug) for 5 minutes, then restart. If the code comes back, call a technician. |
E11 / E12 (front-load) |
Some front-load models: blower motor not turning properly (E11), or blocked airflow (E12). | Clean the lint screen, the lint trap housing and the full vent run to the outside. If E11 returns, call a technician. |
E16 / E17 / E18 (front-load) |
Some front-load models: drum motor not turning or centrifugal switch fault (E16), communication failure between the machine control and the user interface (E17), or between the user interface and the motor drive (E18). Call a technician |
Turn off power at the breaker (or unplug) for 5 minutes, then restart. If the code comes back, call a technician. |
E60 |
Some newer models: door switch malfunction. Call a technician |
Close the door firmly and make sure the latch catches. If the code returns, call a technician. |
E61 |
Depending on model: L2 and neutral wired incorrectly at the terminal block (input voltage too high, DBVH512-type models), or outlet thermistor open (some front-load models). Call a technician |
Do not touch the terminal block. Have a technician or electrician check the power cord and wiring. |
E62 |
Commonly reported as a system contact error (a loose connection somewhere in the system); some technicians also tie it to a stuck key. Call a technician |
Turn off power at the breaker (or unplug) for 5 minutes, then restart. If the code comes back, call a technician. |
E80 / E81 |
Some newer models: invalid user interface model (E80) or invalid power board model (E81), usually after a board replacement. On some front-load models E81 means the input voltage is too high. Call a technician |
Turn off power at the breaker (or unplug) for 5 minutes, then restart. If the code comes back, call a technician. |
353 / F353 |
GE Profile UltraFast Combo washer/dryer: the lint filter is clogged, usually with fabric softener residue. | Unplug the unit, separate and rinse the foam filter, scrub the mesh screen, reinstall it and run a cycle. |
1 or 2 on display (2019+ models) |
Not a fault: a setup setting that tells the control whether the dryer is electric (1) or gas (2). | Press Start to toggle it if it is wrong for your dryer, or check your manual. |
What we actually find on GE dryers in the Denver area
The codes above come from GE’s own documentation. This section shows what our technicians found once they opened the machine. Since 2023 we have handled 52 GE dryer service calls across the Denver metro and Boulder County. Every number here comes from our own job records.
The dryer repairs we do most often (all brands)
Our notes on GE dryers are too thin to rank by brand alone, so here is what we found across all 983 dryer calls in our records:
- Heating element: 88 calls
- Drive belt: 35 calls
- Idler pulley or drum rollers: 33 calls
- Clogged vent or lint: 29 calls
- Thermal fuse or thermostat: 27 calls
- Control board: 26 calls
- Thermistor or sensor: 20 calls
Recent GE dryer calls
- Broomfield (80023), May 2026: GE dryer making noise. Repair: idler pulley or drum rollers replaced (WE03X26413).
- Denver (80202), February 2026: GE dryer not starting. Diagnosis: thermal fuse or thermostat.
- Longmont (80504), March 2025: GE dryer not heating. Diagnosis: thermistor or sensor (part WE04X26216).
GE dryer repairs from $250. Home diagnostic visit from $59, credited toward your repair. Call 720-230-1229.
Source: The Appliance Team service records, 2023–2026. Customer details removed.
Video: GE dryer troubleshooting
Video by Stimwalt Studios
What we see on Denver calls
- Across all 983 dryer calls in our records (all brands), the repairs we do most often: heating element (88 calls), drive belt (35) and idler pulley or drum rollers (33).
- Recent call: Broomfield (80023), May 2026: GE dryer making noise. Repair: idler pulley or drum rollers replaced (WE03X26413).
Don’t want to do it yourself? Call 720-230-1229.
What you can safely check yourself
- Unplug the dryer, and turn off the gas valve on gas models, before any hands-on check.
- Clean the lint filter before every load.
- Disconnect and vacuum the vent duct, and replace crushed or plastic foil duct.
- Check that the outside vent hood opens freely and is not blocked.
- Press each control button to free any that are stuck.
- For other codes, unplug the dryer for 3 minutes, then restart once.
When to call a technician
- A thermistor, motor or control board code comes back after a reset.
- The dryer runs but does not heat, or it gets very hot on the outside.
- You smell burning or gas.
- The drum will not turn, or the motor keeps running with the dryer off.
- A miswiring code (007/F07) appears.
How to prevent this
Many of these breakdowns start with maintenance that was skipped. These guides show what to check, how often, and what happens if you don't:
Frequently asked questions
How do I reset a GE dryer error code?
Unplug the dryer or switch off its breaker for about 3 minutes, then restore power and start a new cycle. If the cause is still there, the code will come back.
What does Check Vent mean on a GE dryer?
The dryer sensed low airflow, which usually means lint or a crushed duct is blocking the vent. Clean the duct and outside hood right away; a blocked vent makes drying slow and raises the fire risk.
Why does my GE dryer show 002 or 004?
These codes point to the outlet thermistor, the sensor that reads exhaust temperature, or its wiring. A technician can test the sensor's resistance and replace it if it is out of range.
Is F010 or F011 a problem?
No. F010 means the drum was empty and F011 means the load was already dry. Start a new cycle with wet laundry and the code clears.
Sources: searspartsdirect.com, searspartsdirect.com, products.geappliances.com, products.geappliances.com, appliancepartspros.com, appliancepartspros.com, needapplianceparts.com, manualslib.com, forum.upfix.com, appliancepartspros.com, products.geappliances.com, washerfixlab.com, removeandreplace.com. Codes and meanings can vary by model; check your owner's manual.