Commercial refrigerator repair for reach-ins, prep tables, undercounter units, bar coolers and glass-door merchandisers in 52 Denver-area cities. Since 2024 our technicians have taken roughly 155 commercial refrigeration calls from restaurants, convenience stores, bars, schools and offices. This page is built from those tickets and from photos taken on site.

~155commercial refrigeration calls since 2024
$129commercial diagnostic, credited to the repair
41°Fthe cold-holding line we work to protect
90 dayswarranty on parts and labor

What 155 commercial calls tell us

Each ticket records the complaint and what the technician found. Counts are rounded, and one ticket can fall in more than one row.

What the customer reported Tickets What we usually found
Running warm, food at risk ~40 Dirty condenser, failed condenser or evaporator fan, iced coil, low refrigerant, compressor
Unit stopped completely ~30 Contactor or relay, controller, compressor, tripped breaker or blown fuse
Scheduled check or cleaning ~25 Condenser cleaning, drain cleaning, gasket and hinge inspection
Door, gasket or hinge trouble ~17 Torn gasket, sagging door, broken hinge or cam
Ice on the coil or frost ~13 Defrost heater or termination failure, clogged drain, door left open
Water leaking ~9 Clogged or cracked drain line, frozen drain
Noise ~8 Fan motor bearings, blade hitting ice, compressor strain
Alarm or error code ~7 High-temperature alarm, sensor fault, defrost fault

Equipment we work on

Reach-in

Reach-in refrigerators and freezers

One-, two- and three-door units from True, Turbo Air, Atosa, Avantco, Beverage-Air, Delfield and Imperial.

Prep

Prep tables and sandwich units

Pizza and salad prep tables, Everest and True prep lines, chef bases and worktop units.

Bar

Bar and beverage coolers

Back-bar coolers, beer and keg coolers, glass-door bottle coolers, Perlick undercounter units.

Retail

Merchandisers and display cases

Glass-door coolers in convenience stores, Hill Phoenix freezers, ice cream and novelty cases.

Walk-ins have their own pages: walk-in cooler repair and walk-in freezer repair.

The repairs behind the numbers

Dust-clogged condenser coil on a commercial reach-in refrigerator before cleaning

Running warm: start with the condenser

Most warm-box calls start here. Kitchen grease and dust block the condenser, the compressor runs nonstop and the box creeps above 41°F. We clean the coil, check the condenser fan and only then look at refrigerant and the compressor.

Do this monthly: brush or vacuum the condenser. It is the cheapest repair there is.

Heavy frost on the door frame of a commercial undercounter refrigerator

Frost and ice: doors, gaskets and defrost

Frost on the frame like this means warm, humid air is getting in. A torn gasket or a door that does not close lets moisture in, and the coil ices over. If the gasket is fine, we test the defrost heater, termination sensor and drain.

Quick check: close the door on a dollar bill. If it slides out easily, the gasket is not sealing.

Testing the condensing unit of a Turbo Air commercial freezer in Boulder

Fans: small motors, big consequences

When the evaporator fan stops, the coil freezes and the box warms up even though the compressor runs. When the condenser fan stops, the compressor overheats. Both are quick swaps if caught early.

Signs: no airflow inside the box, a hot compressor area, grinding or ticking noise.

Compressor compartment of a built-in commercial refrigerator in Denver that stopped cooling

Stopped completely: controls before compressors

A dead unit is often a contactor, a relay, a controller or a tripped breaker, not a compressor. We test the cheap parts first. When the compressor really is gone, we quote it against replacing the unit so you can decide.

Parts we replace most: compressors (~15 tickets), controllers and boards (~12), sealed-system work (~10).

True commercial freezer digital temperature controller display

Alarms and error codes

Modern True, Turbo Air and Beverage-Air units log high-temperature alarms and sensor faults. We read the code, test the probe and check the defrost settings before replacing a controller.

Tip: take a photo of the code before you power-cycle the unit.

How a service call works

  1. Call or book onlineTell us the brand, model and what the unit is doing.
  2. Same-day or next-day visitCommercial refrigeration gets priority because food is at risk.
  3. Written quoteDiagnosis and price before any work. The $129 diagnostic is credited to the repair.
  4. Repair and verifyWe confirm the box pulls down to temperature before we leave.

From our service tickets

Denver · prep line

An 11-year-old True prep line

The unit had gone completely warm. After ruling out the condenser, fans and controls, the diagnosis came down to the compressor.

Arvada · reach-in

Imperial fridge dead after defrost

The unit stopped working right after a defrost cycle. Testing showed a failed compressor, not a defrost part.

Boulder · bar

Back in service after sitting idle

A Perlick undercounter refrigerator that had sat unused in a seasonal space was checked over and brought back into service.

Keep your reach-ins out of the danger zone

  • Log temperatures twice a day. Catch the drift before the inspector does.
  • Clean condenser coils monthly, every two weeks near fryers.
  • Do not overfill prep rails above the fill line.
  • Leave space around the vents. Boxes stacked against them block airflow.
  • Replace torn gaskets right away.
  • Keep the drain line clear to stop leaks and ice.

Related pages:

Commercial refrigerator problems we fix

01
Running warm above 41°F
02
Unit stopped completely
03
Ice or frost on the coil
04
Water leaking inside or under the unit
05
Door, gasket or hinge problems
06
Noisy fans or compressor
07
High-temperature alarms and error codes
08
Condenser cleaning and scheduled checks
Commercial Refrigerator Repair in Denver
Pricing

How much does commercial refrigerator repair in Denver cost in Denver?

Commercial diagnostics are $129, credited toward the repair. You get a written quote before any work starts, and repairs carry our 90-day parts and labor warranty.

$129Diagnostics, credited to repair
WrittenQuote before work
90 daysParts & labor warranty
See full price list →
Brands We Service

Frequently Asked Questions

Commercial diagnostics are $129 and are credited toward the repair. After diagnosis you get a written quote for parts and labor before any work begins, and every repair has a 90-day parts and labor warranty.

On our tickets the top causes are a dirty condenser coil, a failed condenser or evaporator fan, an iced evaporator, low refrigerant and, less often, a failing compressor. We check them in that order.

Most commercial refrigeration calls get a same-day or next-day visit because food is at risk. Call 720-230-1229 and tell us the box temperature.

Yes. See our walk-in cooler and walk-in freezer pages. We also repair commercial ice machines and kitchen equipment.

If the compressor and cabinet are sound, fans, controls, gaskets and contactors are worth repairing. If the compressor has failed on an old unit, we give you the repair quote so you can compare it with the cost of a new unit.

Box running warm? Call before you lose product.

Call 720-230-1229 or book online. Same-day or next-day commercial refrigeration service across the Denver metro.

Other Services We Offer

720-230-1229
720-230-1229
Call Now Book Online

See our technicians at work

Real service calls from our team across the Denver metro. Tap the video to turn on sound.

Commercial Refrigeration Repair in Denver | Walk-in Freezers & Store Coolers