If your Maytag refrigerator shows PO, the power was out long enough to warm the freezer. Temperature Alarm means one side stayed warm for an hour and a half. A blinking F, often with an F#E# number, means the control logged a part failure, and Maytag’s guidance is a one-minute power cut followed by a service call if it repeats. In Whirlpool-platform service literature, F3 points to sensors, F4 to heaters, F6 to boards, F7 to the sealed system and F8 to the ice maker.
Maytag refrigerators share their electronics with the rest of the Whirlpool family. Maytag explains its alarms publicly but leaves the F#E# numbers undefined, so the code meanings here are taken from Whirlpool-platform service documents and may differ slightly by model. Several displays are simple reminders, not failures. We have arranged the codes by the symptom you are most likely noticing, because that is usually how people find this page: a warm fridge, a frosted freezer, no ice, or a strange message.
Maytag refrigerator codes by symptom
“The fridge is warm” or an alarm is sounding
| Code | Likely cause on a Maytag | Before you call |
|---|---|---|
PO |
Outage long enough for the freezer to pass 18 °F (-8 °C). It chimes three times. | Touch Measured Fill under the blinking Confirm, then sort through anything that thawed. |
| Temperature Alarm | Fresh food over 48 °F (9 °C) or freezer over 15 °F (-9 °C) for 90+ minutes. Sound stops on recovery; light keeps blinking. | Press Alarm. Typical causes: door not latched, vents buried in groceries, dusty coils. |
| Cooling Off | Someone switched cooling off, often while wiping the panel. Lights still work. | Hold the two keys your manual lists (often Lock and Measured Fill) for 3 seconds. |
F3E0, F3E1, F3E2 |
Commonly reported: fresh-food or main thermistor (E0, E1), freezer thermistor (E2). The unit may drop into backup cooling. Technician |
Power off one minute; if the F comes back, write it down and book. Keep a thermometer inside meanwhile. |
F6E1, F6E2 |
Commonly reported: main control lost the display (E1) or an expansion board (E2). Technician |
Power off one minute; if the F comes back, write it down and book. |
F7E1 |
Commonly reported: sealed system fault, compressor or refrigerant. Technician |
Book right away; refrigerant work is never DIY. |
C, CF, d (older displays) |
Sensor failure (C), board-to-display communication (CF), stuck air damper (d). Technician |
Five minutes unplugged and make sure food is not blocking the vents. |
“There is frost or sweating”
| Code | Likely cause on a Maytag | Before you call |
|---|---|---|
F4E1, F4E2, F4E3 |
Commonly reported: defrost heater for the freezer or main evaporator (E1), fresh-food evaporator (E2), convertible section (E3). Technician |
A white sheet of frost on the freezer back panel confirms it. |
F4E8, F4E9, F4ED, F4EE |
Commonly reported: mullion heater (E8), dispenser wall heater (E9), damper heaters (ED, EE). Technician |
Expect moisture or ice near that spot until repaired. |
F3E8, F3E9 |
Commonly reported: room humidity sensor (E8) or room temperature sensor (E9), which steer the anti-sweat heaters. Technician |
Cooling continues; door edges may sweat. |
F3E3, F3E4, F3E5, F3EB |
Commonly reported: pantry or convertible drawer (E3, EB), deli drawer (E4), crisper or defrost sensor by model (E5). Technician |
Power off one minute; if the F comes back, write it down and book. |
F3EC, F3ED, F3EF |
Commonly reported: French-door mullion sensor (EC), door ice box (ED), second freezer evaporator (EF). Technician |
Power off one minute; if the F comes back, write it down and book. |
“No ice” or dispenser problems
| Code | Likely cause on a Maytag | Before you call |
|---|---|---|
F8E1, F8E2, F8E3, F8E8, F8EC |
Commonly reported: ice box sensor (E1), fresh-food ice maker tray or harvest (E2, E3), freezer ice maker tray or harvest (E8, EC). Technician |
Cycle the ice maker off and on and break up any jammed cubes. |
Ice maker E0 to E5 (service mode) |
No error (E0), not cooling (E1), motor lost position (E2), heater timeout (E3), dry cycles (E4), mold sensor (E5). | Normally visible only in test mode. |
Reminders, lights and test readouts
| Code | Likely cause on a Maytag | Before you call |
|---|---|---|
| Door Alarm, Door Ajar | A door or the freezer drawer has stayed open a few minutes. | Push bins in and check the fridge is level so the doors self-close. |
H2O, Water or Air Filter light |
Filter reminders only. | Replace the filter and hold reset (often 3 seconds). |
F9E1, F9E3, F9E4 |
Commonly reported: LED lights in the fresh-food ceiling (E1), freezer (E3) or side walls (E4). | No effect on cooling; book when convenient. |
EO, ES, CL, Error (service mode) |
Thermistor open (EO) or shorted (ES); boards not communicating (CL, Error). Technician |
If seen in normal use, unplug five minutes, then book. |
What we actually find on Maytag refrigerators in the Denver area
The codes above come from Maytag’s own documentation. This section shows what our technicians found once they opened the machine. Since 2023 we have handled 16 Maytag refrigerator service calls across the Denver metro and Boulder County. Every number here comes from our own job records.
The refrigerator repairs we do most often (all brands)
Our notes on Maytag refrigerators are too thin to rank by brand alone, so here is what we found across all 1685 refrigerator calls in our records:
- Compressor or sealed system: 167 calls
- Evaporator or condenser fan: 121 calls
- Control or inverter board: 120 calls
- Ice maker: 109 calls
- Defrost system: 66 calls
- Thermistor or sensor: 37 calls
- Water inlet valve: 32 calls
Maytag refrigerator repairs from $320. Home diagnostic visit from $59, credited toward your repair. Call 720-230-1229.
Source: The Appliance Team service records, 2023–2026. Customer details removed.
Video: Maytag refrigerator error codes
Video by Refrigerator Reviews
What we see on Denver calls
- An error code points to the system that reported the fault, not always to the part that failed.
- Across all 1685 refrigerator calls in our records (all brands), the repairs we do most often: compressor or sealed system (167 calls), evaporator or condenser fan (121) and control or inverter board (120).
Don’t want to do it yourself? Call 720-230-1229.
What to do while you wait
- Cut power for one minute and restore it, once.
- Check that Cooling Off is not lit and every door seals.
- Pull food away from the vents in both sections.
- Unplug and vacuum the coils behind the bottom grille.
- Monitor with thermometers: 37 °F fresh food, 0 °F freezer.
Call for service when
- The blinking F returns after the power cut.
- The fridge sits above 40 °F or the freezer above 10 °F for hours.
- Frost covers the freezer back wall.
- F7E1 appears, or the compressor runs and nothing gets cold.
How to prevent this
Many of these breakdowns start with maintenance that was skipped. These guides show what to check, how often, and what happens if you don't:
Maytag refrigerator code FAQ
How do I reset a code on my Maytag refrigerator?
Unplug it or switch off the breaker for one minute and restore power. A code that comes back is a real fault.
What does PO mean?
A power outage let the freezer climb to about 18 °F. Confirm the alert and check frozen food.
What does F3E1 mean on a Maytag?
Service references link it to the fresh-food or main temperature sensor. The fridge may keep cooling on a timer until it is replaced.
My Maytag says Cooling Off. Is it broken?
No. Cooling was switched off at the panel; turn it back on with the key combination in your manual.
Sources: producthelp.maytag.com, producthelp.maytag.com, producthelp.maytag.com, producthelp.maytag.com, producthelp.maytag.com, producthelp.whirlpool.com, producthelp.whirlpool.com, producthelp.whirlpool.com, searspartsdirect.com, appliancepartspros.com, mypros.plus, mypros.plus, mypros.plus. Codes and meanings can vary by model; check your owner’s manual.