On a Maytag dryer, AF (or F4E3) is a blocked vent, PF is a power blip, and L2 (or F4E4) means the dryer is getting power on only half of its 240-volt circuit. Those three are usually fixable at home: clean the lint path, press Start, check the breaker. Codes about sensors, the heater relay, the drive motor or the boards need a technician.

Late-model Maytag dryers run Whirlpool controls, so the alternating F#E# format is the same. Two older families use their own codes: Bravos dryers show F-01 style codes, and Neptune dryers show plain two-digit numbers. If a code is not on this page, the tech sheet tucked inside the console has the definitive list for your model. Always unplug before reaching inside, and on a gas dryer leave the gas valve and burner to a professional. Codes marked “older” or “commonly reported” come from parts and repair references rather than Maytag’s own pages.

Maytag dryer codes, by what they affect

Airflow and power supply

Code What the dryer detected What we would do
AF, F4E3 Exhaust air is not getting out: full lint screen, packed vent, a crushed foil hose behind the dryer or a run with too many elbows. The cycle continues but takes much longer. Empty the screen, pull the dryer out and straighten the hose, then make sure the outside hood flap swings open. Press any key to clear. A long run needs professional vent cleaning.
PF Power dropped during a cycle. Hold Start to continue, or press Power to clear.
L2, F4E4 Electric dryers: one leg of the 240 V supply is low or missing. The drum spins but there is no heat. Reset the double breaker fully off and on (or replace the fuse), then run Timed Dry. Still there? An electrician should check the outlet.

Heat and sensing

Code What the dryer detected What we would do
F3E1 Exhaust thermistor reads out of range.
Technician
Clear the lint path first, then reset. A repeat means the thermistor or harness.
F3E3 Inlet thermistor (at the heater) reads out of range.
Technician
Reset once, then service.
F3E2 Moisture sensor fault; auto-dry cycles quit early or run forever.
Technician
Scrub the two metal strips inside the drum to remove softener film.
F3E5 Rear-sensor models: several loads finished with no usable moisture reading. An unlevel cabinet or tiny loads that never touch the bars are typical causes. Level the dryer, dry full loads, wipe the bars with rubbing alcohol.
F3E4 Listed by Whirlpool without a public definition; usually treated as a temperature or moisture sensing fault.
Technician
Five-minute power reset, then service if it returns.
F4E1, F4E2 Heater relay on the control is failing, so heat may never come on.
Technician
The relay, element or gas valve circuit needs testing. Do not open a gas valve yourself.

Motor, door and control boards

Code What the dryer detected What we would do
F1E1 Centennial-type boards: motor relay stuck closed.
Technician
A few minutes off at the breaker; a repeat means the board.
F1E3 Control board does not match the dryer, typically after a board swap.
Technician
Needs the correct part number.
F1E4, F1E5 Control unit or its wiring, per Whirlpool’s support listing.
Technician
Five-minute reset first.
F2E1 A key on the panel is stuck. Press each key firmly. One that stays down means a new interface.
F2E2 Keypad or control fault; a loose ribbon cable is a common cause.
Technician
Reset, then have the cable and keypad checked.
F2E4, F2E5 Software error inside the user interface.
Technician
Reset at the breaker.
F5E1 Commonly reported as the door switch: the board cannot tell if the door is shut.
Technician
Make sure the door latches firmly, then reset.
F6E1, F6E2, F6E3 Main board and touch panel stopped communicating.
Technician
Usually a harness connection or one of the two boards.
F7E1 Drive motor, its circuit or wiring.
Technician
Check that nothing is wedged between the drum and the front panel.
F9E2, FCE1, 0E, 0g, 3E, 6E, -:-- Listed by Whirlpool on some models with only a reset procedure and no published meaning. Five minutes unplugged. If it returns, a tech diagnoses with a meter.

Older Bravos and Neptune dryers

Code What the dryer detected What we would do
F-01, F-02 Bravos: main control failure (F-01) or a stuck key (F-02).
Technician
Unplug five minutes. Work each key for F-02.
F-22, F-23 Bravos: exhaust thermistor.
Technician
Clean the lint path, then service.
F-26 Bravos: drive motor.
Technician
Make sure the drum is free to turn.
F-28, F-29 Bravos: moisture sensor.
Technician
Clean the drum sensor strips.
01, 02, 03, 04, 08 Neptune: thermistor (01), no heat (02), door switch (03), motor relay on the board (04), stuck key (08).
Technician
For 01 and 02, clean the vent and check the breaker; on gas units confirm the supply valve is open but go no further.

What we actually find on Maytag dryers in the Denver area

The codes above come from Maytag’s own documentation. This section shows what our technicians found once they opened the machine. Since 2023 we have handled 98 Maytag dryer service calls across the Denver metro and Boulder County. Every number here comes from our own job records.

The Maytag dryer repairs we do most often

Across all 98 Maytag dryer calls, with or without a code on the display:

  1. Heating element: 8 calls
  2. Drive belt: 6 calls
  3. Idler pulley or drum rollers: 5 calls
  4. Clogged vent or lint: 2 calls

Recent Maytag dryer calls

  • Longmont (80504), September 2026: Maytag dryer not heating. Repair: heating element replaced.
  • Longmont (80503), July 2026: Maytag dryer not starting. Diagnosis: idler pulley or drum rollers.
  • Longmont (80504), January 2026: Maytag dryer ice maker not working. Repair: drive belt replaced.
  • Erie (80516), December 2025: Maytag dryer making noise. Repair: idler pulley or drum rollers replaced.

Maytag dryer repairs from $310. Home diagnostic visit from $59, credited toward your repair. Call 720-230-1229.

Source: The Appliance Team service records, 2023–2026. Customer details removed.

Video: Maytag dryer error codes

Video by Mad Scientist Hut

What we see on Denver calls

  • An error code points to the system that reported the fault, not always to the part that failed.
  • The Maytag dryer repairs we do most often across the Denver metro and Boulder County: heating element (8 calls), drive belt (6) and idler pulley or drum rollers (5).
  • Recent call: Longmont (80504), September 2026: Maytag dryer not heating. Repair: heating element replaced.

Don’t want to do it yourself? Call 720-230-1229.

A quick routine before calling

  1. Unplug the dryer or switch off both breaker handles.
  2. Wash the lint screen in soapy water if you use dryer sheets; residue clogs the mesh even when it looks clean.
  3. Slide the dryer out, check the hose for crushed spots, and go outside to watch the hood flap open while it runs.
  4. For a no-heat complaint, look at the breaker panel before anything else.
  5. Restore power and run one Timed Dry cycle to see whether the code comes back.

Stop and book service if

  • You smell gas or something burning, or see scorch marks.
  • The drum grinds, squeals or will not turn.
  • It tumbles but stays cold with the breaker on and the vent clear.
  • AF still appears after the screen and the entire vent run are clean.

How to prevent this

Many of these breakdowns start with maintenance that was skipped. These guides show what to check, how often, and what happens if you don't:

All appliance maintenance guides →

Maytag dryer code FAQ

Do Maytag and Whirlpool dryers use the same codes?

Current models do, because Whirlpool builds both. Older Bravos and Neptune dryers have their own lists, shown in the last table.

How do I clear a code on my Maytag dryer?

Most clear with any key press once the cause is fixed. For F#E# codes, switch off the breaker for one to five minutes and run Timed Dry.

My Maytag says AF but the lint screen is clean. Why?

The blockage is usually further along: in the hose behind the dryer, inside the wall duct, or at a stuck outside flap.