Kenmore dryers were built by three different manufacturers, and the model number tells you which: 110 means Whirlpool, 796 means LG, 417 means Frigidaire/Electrolux. Whatever the maker, the codes we run into most are airflow warnings (AF, F-30, F4E3, E8C), temperature sensor faults (F3E1, F-22, E1, tE1, E24) and heat faults (E4A, E5B, F4E1). Start with the lint screen and the vent; sensor, heater and control codes call for a technician.
A Kenmore dryer keeps the code vocabulary of the factory that built it, so the first job is reading the label inside the door opening or on the rear panel and taking the three digits before the dot. Within the Whirlpool family, older Oasis and VMax controls show dashed codes like F-22 while newer ones alternate F#E# codes. The 417 family also includes compact condensing dryers with their own E-number set. Unplug the dryer before inspecting anything, and on gas units close the gas shutoff. Meanings come from Sears parts documents, the makers’ own pages and repair references, and can shift between series.
Kenmore dryer codes, by who built the dryer
110 models (Whirlpool-built): airflow, power and heat
| Code | Meaning on this Kenmore family | Suggested step |
|---|---|---|
AF, F-30, F4E3 |
Exhaust airflow is restricted: packed lint screen, clogged duct, crushed hose or too many turns. | Clean the screen, pull the dryer out and clear the duct to the outside hood. Watch the flap open while it runs. |
PF |
A power interruption stopped the cycle. | Press Start to continue or Stop/Cancel to clear. Frequent PF hints at a loose cord or outlet connection. |
F-31, F4E4, F-42, F-43 |
Electric units: one 240 V leg low or missing (F-31, F4E4), or general undervoltage (F-42, F-43). Drum spins, no heat. Technician |
Cycle both breaker handles. If it returns, the outlet, cord and terminal block need checking. |
F-20, F-21, F4E1, F4E2 |
Heater relay failed, so heat may not come on. Technician |
Unplug five minutes and try again; a repeat needs a repair visit. |
110 models: sensors, motor and controls
| Code | Meaning on this Kenmore family | Suggested step |
|---|---|---|
F-22, F-23, F3E1, E1, E2 |
Exhaust thermistor open or shorted. A good one reads about 10,000 ohms at room temperature. Technician |
Unplug five minutes and try again; a repeat needs a repair visit. |
F-24, F-25, F3E3 |
Inlet thermistor at the heat source. Technician |
Inlet thermistor/high-limit assembly or its wiring. |
F-28, F29, F3E2 |
Moisture sensor fault; auto cycles end too soon or never end. | Wipe the drum sensor bars with rubbing alcohol and make sure no metal touches them. Use Timed Dry meanwhile. |
F-26 |
Drive motor. Technician |
Unplugged, the drum should turn by hand; do not overload. |
F-40, F-41, F-44, F-45, F-46 |
Oasis-type dryers with a separate blower control: communication (F-40), blower motor (F-41, F-46), blower board (F-44), blower speed sensor (F-45). Technician |
Clear the vent, unplug five minutes, then the blower, thermal fuse or blower board gets diagnosed. |
F-01, F1E1 |
Main board failure; on VMax-style boards F1E1 is a stuck motor relay. Technician |
Unplug five minutes and try again; a repeat needs a repair visit. |
F1E3, E3 |
Board and interface do not match, typically after a part swap. Technician |
Verify the replacement part number. |
F-02, F2E1, F2E4, F2E5 |
Stuck key (F-02, F2E1) or interface software error (F2E4, F2E5). Technician |
Press each key firmly, unplug five minutes. |
F6E2, F6E3 |
Board and interface not communicating. Technician |
Usually a harness or one of the boards. |
F-47 |
Unused; can show in diagnostic mode only. | Ignore if the dryer works. |
796 models (LG-built)
| Code | Meaning on this Kenmore family | Suggested step |
|---|---|---|
tE1, tE2 |
Outlet (exhaust) thermistor. Technician |
Clean the screen and vent, unplug five minutes. |
tE3, tE5, tE6, tE7 |
Hybrid heat-pump units: heater thermistor (tE3) or compressor and evaporator thermistors (tE5 to tE7). Technician |
Heat pump parts are technician-only. |
tE4, Add Water |
Steam models: steam generator thermistor (tE4), or the steam reservoir is empty. | Refill the reservoir. tE4 after a restart means the steam generator. |
dE |
Door reads open. | Shut it firmly and check for fabric in the seal. |
PS |
Power supply fault, often a cord wired wrong at the back. Technician |
Reset breakers; on a new install, have the cord checked against the instructions. |
EE, E13, F0 |
Hybrid units: board software (EE), drain pump (E13), lint filter missing (F0). | Fit the filter for F0, unkink the drain hose for E13, restart for EE. |
417 models (Frigidaire/Electrolux-built)
| Code | Meaning on this Kenmore family | Suggested step |
|---|---|---|
E10, E11, E12, EAF |
Board communication error or failed board. Technician |
Unplug five minutes and try again; a repeat needs a repair visit. |
E24, E25 |
Thermistor open or shorted; this family uses roughly 50,000 ohm sensors. Technician |
Resistance test of the sensor and wiring. |
E4A |
Cycle ran far too long, usually because heat is weak. Technician |
Clean the lint path; if it is not heating, the element (electric) or burner parts (gas) are next. |
E5B |
No heat. Technician |
Electric: check the breaker. Gas: confirm the shutoff behind the dryer is open, nothing more. |
E68 |
Stuck button. | Press firmly; a key that stays stuck means a new control. |
E8C |
High-limit thermostat tripped too often: overheating from poor airflow. | Clear the full vent run. Clean vent and the code persists? The blower and controls get checked. |
417 compact condensing dryers
| Code | Meaning on this Kenmore family | Suggested step |
|---|---|---|
EH1, EH2, EH3 |
Supply voltage problem. Technician |
An electrician should confirm 208 to 240 V at the outlet. |
Ex21, Ex22, Ex31, Ex32, Ex45 |
Condensate pump (21, 22), humidity sensor (31, 32), door open (45). The x digit varies. | Empty the water box, check the drain hose, close the door firmly. |
E51 to E5H |
Motor or inverter, including overload overheating (E52) and jammed drum (E54). Technician |
Remove some clothes and let it cool 30 minutes. |
E62, E63, E64, E71, E83 to E9E, EH1 to EHF |
Heat pump compressor (E62 to E64), temperature sensor (E71), board, interface or power supply. Technician |
Unplug five minutes and try again; a repeat needs a repair visit. |
What we actually find on Kenmore dryers in the Denver area
The codes above come from Kenmore’s own documentation. This section shows what our technicians found once they opened the machine. Since 2023 we have handled 47 Kenmore dryer service calls across the Denver metro and Boulder County. Every number here comes from our own job records.
The dryer repairs we do most often (all brands)
Our notes on Kenmore dryers are too thin to rank by brand alone, so here is what we found across all 983 dryer calls in our records:
- Heating element: 88 calls
- Drive belt: 35 calls
- Idler pulley or drum rollers: 33 calls
- Clogged vent or lint: 29 calls
- Thermal fuse or thermostat: 27 calls
- Control board: 26 calls
- Thermistor or sensor: 20 calls
Recent Kenmore dryer calls
- Thornton (80602), April 2026: Kenmore dryer making noise. Repair: thermistor or sensor replaced (6631EL3003B).
- Arvada (80007), April 2026: Kenmore dryer stopping mid-cycle. Repair: thermal fuse or thermostat replaced.
- Denver metro, August 2025: Kenmore dryer not heating. Repair: heating element replaced (WP3977678).
- Boulder (80302), December 2024: Kenmore dryer not starting. Diagnosis: motor.
Kenmore dryer repairs from $290. Home diagnostic visit from $59, credited toward your repair. Call 720-230-1229.
Source: The Appliance Team service records, 2023–2026. Customer details removed.
Video: Kenmore dryer heating element repair
Video by Parts Dr
What we see on Denver calls
- The video shows a heating element repair. It is the most common dryer repair on our calls (all brands).
- Across all 983 dryer calls in our records (all brands), the repairs we do most often: heating element (88 calls), drive belt (35) and idler pulley or drum rollers (33).
- Recent call: Thornton (80602), April 2026: Kenmore dryer making noise. Repair: thermistor or sensor replaced (6631EL3003B).
Don’t want to do it yourself? Call 720-230-1229.
Before you book a Kenmore dryer repair
- Note the model prefix (110, 796 or 417).
- Unplug the dryer; leave gas lines and the burner alone.
- Wash the lint screen if dryer sheets have glazed it.
- Clear the duct to the outside and swap out crushed foil hose.
- Electric dryer turning without heat? Reset both breakers.
- Clean the moisture bars, then try one cycle.
Bring in a technician if
- A sensor, heater, motor or board code is back after the reset.
- Clothes stay damp and cold with a clean vent.
- You smell gas or burning, or clothes come out scorched.
- Voltage codes show up; the outlet and cord need a safe check.
How to prevent this
Many of these breakdowns start with maintenance that was skipped. These guides show what to check, how often, and what happens if you don't:
Kenmore dryer code FAQ
Who made my Kenmore dryer?
Look at the model prefix: 110 is Whirlpool, 796 is LG, 417 is Frigidaire/Electrolux.
What does AF mean?
On a Whirlpool-built 110 dryer it means restricted airflow. Clean the lint screen and the vent run.
How do I reset my Kenmore dryer?
Unplug it, or turn off both breakers, for about five minutes and start a new cycle.
My Kenmore shows E1 or E2. What is that?
On 110 models it is the exhaust thermistor reading open or shorted. If a reset does not clear it, the sensor or wiring needs testing.
Sources: searspartsdirect.com, searspartsdirect.com, searspartsdirect.com, searspartsdirect.com, searspartsdirect.com, searspartsdirect.com, searspartsdirect.com, searspartsdirect.com, searspartsdirect.com, ifixit.com, appliancepartspros.com. Codes and meanings can vary by model; check your owner’s manual.