When a Frigidaire refrigerator is warm but the freezer still works, the cause on our Denver-area calls was usually the defrost system (an iced-up evaporator coil), a stuck air damper or a failed control board. When both sections are warm, it is more often a sealed-system problem, such as a failed compressor or a leaking evaporator. Check that the vents are clear, the doors seal and the condenser coils are clean, and if the fridge is still warm after a few hours, call a technician.
Frigidaire refrigerators, from basic top-freezers to Gallery and Professional models, are common in Denver-area homes and rentals. Since January 2024 our technicians have taken more than 15 Frigidaire calls where the refrigerator was not cooling or the temperature was off, in Brighton, Arvada, Lafayette, Golden, Littleton, Thornton and other cities.
Checks you can do yourself
- Check the settings and the temperature alarm. Many Frigidaire models beep and flash a temperature warning. Make sure the controls were not changed by accident.
- Clear the vents between the freezer and the fresh food section. Cold air for the fridge comes from the freezer.
- Look at the back wall of the freezer. Heavy frost or a solid sheet of ice behind the panel is a sign of a defrost problem.
- Check the door gaskets. A torn or folded gasket lets warm air in all day.
- Clean the condenser coils under the front grille or at the back.
- Listen for the fans. The freezer fan should run when the compressor runs.

What we found on Frigidaire “not cooling” calls
| Date | City | Problem | What we found or did |
|---|---|---|---|
| Oct 2026 | Arvada | Temperature going up and down, ice maker dripping | Air damper stuck closed; ice maker and damper repair |
| Apr 2026 | Brighton | High temperature alarm, freezer food melting | Replaced the ice maker fill tube |
| Jan 2026 | Golden | Not cooling | Replaced the control board |
| Nov 2025 | Lakewood | Freezer working, fridge not cooling | Diagnosed |
| Jun 2025 | Littleton | Not cooling | Replaced the defrost timer |
| Oct 2024 | Thornton | Not cooling | Compressor needed to be replaced |
| Jun 2024 | Littleton | Gallery model, 55°F inside, freezer works | Iced-up evaporator (defrost problem) |
| Jun 2024 | Lafayette | Professional series, not cooling consistently, door alarm | Replaced the evaporator and heat exchanger |
| Mar 2024 | Johnstown | Freezer not cooling | Replaced the control board |
Fridge warm, freezer cold: defrost and damper
On most Frigidaire side-by-side and French-door models, a fan in the freezer pushes cold air into the fresh food section through an air damper. If the defrost system fails, the evaporator coil ices over and air cannot get through, so the fridge warms up first. On older models the defrost is run by a timer, which we replaced on a Littleton call. If the damper sticks closed, the result is the same; on an Arvada call the damper was stuck and the temperature swung up and down.

Both sections warm: compressor and sealed system
If the freezer is warm too and the coil behind the freezer panel is not frosted, the refrigerator is not making cold at all. That is the sealed system: the compressor, the evaporator, the condenser and the refrigerant. In Thornton the compressor needed to be replaced; on a Lafayette Frigidaire Professional the evaporator and heat exchanger were replaced. Our technicians are EPA 608-certified, and on sealed-system work they pressure test with nitrogen, pull a vacuum and charge the refrigerant by the factory weight.

Control boards
The control board runs the compressor, fans and defrost. When it fails, the refrigerator may stop cooling or the freezer may warm up. We replaced boards on Frigidaire refrigerators in Golden and Johnstown.
From the technician
“If your Frigidaire fridge is warm but the freezer is fine, open the freezer and look at the back panel. Frost all over it means defrost. You can unplug the fridge for a day to melt it, and it will cool again for a while, but the part that failed still needs to be fixed or it comes back.” — Zach, technician at The Appliance Team

Repair cost and booking
Our diagnostic visit is from $59 for homes, and the fee is credited toward the repair if you go ahead. The technician tells you the price before any work starts. We work in 52 Denver-area cities.
- Call 720-230-1229 and tell us the model, how warm it is inside and whether the freezer is still cold.
- See our Frigidaire refrigerator repair page, the Frigidaire refrigerator guide or the general refrigerator not cooling guide.
How to prevent this
Many of these breakdowns start with maintenance that was skipped. These guides show what to check, how often, and what happens if you don't:
Questions we hear on Frigidaire cooling calls
Why is my Frigidaire refrigerator not cooling but the freezer works?
Most often the evaporator coil has iced up because the defrost system failed, or the air damper is stuck closed. Both stop cold air from reaching the fresh food section.
Why is my Frigidaire beeping with a temperature alarm?
The inside got warmer than it should. Check that the doors are closed and sealing. If the alarm keeps coming back, the refrigerator has a cooling problem that needs a technician.
How do I reset my Frigidaire refrigerator?
Unplug it or turn off its breaker for a few minutes, then turn it back on and give it several hours to cool. If it does not, a part has failed.
Is it worth fixing a Frigidaire refrigerator that is not cooling?
Defrost parts, dampers and control boards are usually worth fixing. A compressor or sealed-system repair costs more, and our technician tells you the price before starting so you can decide.